亚洲精品无码AⅤ人在线观看国产_网友分享日韩av无码国产精品心得_嗯啊哦视频在线观看网站_日韩福利免费观看网址_亚洲av精选一区二区_一级α性色生活片久久无码_三级精品少妇影视_欧美成人免费公开播放_久热99这里只有精品_婷婷开心五月四房播播人

Welcome to Dongguan Haochen Hot Runner Technology Co., Ltd!
中文    EN

Haochen 20 years of focus on multimode cavities and small spacing hot runner

Service /


Mobile: 13712972461
Tel: 0769-85478528
400-0988-117
Fax: 0769-85478508
Email: sales@hostar888.com
Website: 51jp.net.cn
Address: No. 11 Zhenlang Road, Wusha Caiwu Industrial Second Road, Chang'an Town, Dongguan City
Company NewsYour location: Home > News > Company News

Analysis of Precautions for Hot Runner Temperature Control Box

Publisher: Administrator Date: 2023-11-02

The hot runner temperature control box should be checked according to safety precautions before use, and the equipment should be turned on after confirmation. So what exactly should be confirmed before use?


1. Check if the thermocouple type on the mold and the thermocouple set on the temperature control card are consistent, that is, "J" or "K" type, which must be consistent.


2. Check if the wiring method of the hot runner on the mold is consistent with the wiring method of the junction box on the temperature control box, especially if the positive and negative poles of the thermocouple are consistent.


3. Check if the equipped cable is suitable for this temperature control box, if the junction box matches, and if the wires and thermocouple wires inside match.


4. Check if the input power cord wiring of the temperature control box is correct.


5. Check the resistance and insulation of the hot runner heater, and then check whether the thermocouple of the hot runner temperature control box is short circuited or open circuited.


6. Connect the cable after the mold is installed on the injection molding machine.


7. Check if the main power switch of the temperature control box and each set of switches are closed. All switches should be closed in advance to avoid burning the thermocouple of the temperature control box or hot runner if the power is connected incorrectly.


8. Check if the input power supply connected to the temperature control box is suitable for the temperature control box, and then connect the cable.


9. Ensure that the grounding wire of the temperature control box is securely connected.


10. Turn on the main power switch.


11. Opening a single set of switches: First, open one set, and then gradually open another set to ensure that if the wrong wire is connected, only one set of temperature control cards or one set of thermocouples will be burned. If there is abnormal sound or display, please do not continue to open other temperature control cards, and immediately check the wiring of each part.


12. Set each group to the desired temperature.


13. Check if the required temperature and stability have been reached.


14. Attention: When unplugging and inserting the temperature control card, be sure to first turn off the power supply of the temperature control box. hot runner system



Dongguan Haochen Hot Runner Technology Co., Ltd
Contact Us:
Mobile: 13712972461
Tel: 0769 85478528/400 0988 117
Fax: 0769-85478508
Email: sales@hostar888.com
Website: 51jp.net.cn
Address: No. 11 Zhenlang Road, Wusha Caiwu Industrial Second Road, Chang'an Town, Dongguan City

粵ICP備18086307號(hào)
CopyRight ? 2023 Dongguan Haochen Hot Runner Technology Co., Ltd. All Right Reserved.

Online
Service

ConsultationTime:9:00-18:00

Select customer service:

Hot
Line

400-0988-117
7*24H Service

Follow
Us

Website
TOP